Finned Tube Air Cooled Heat Exchange Condenser Heat Exchanger

Customization: Available
Condensation Forms: Water-Cooled, Air-Cooled
Refrigerant: CF2Cl2, CF2cl2

Products Details

Basic Info.

Model NO.
CFH
Type
Steam Condenser
Material
Copper, Aluminium
Structural Form
Vertical, Horizontal
Heat Transfer Mode
Regenerative, Regenerative
Form
Shell-Tube
Application Field
Petrochemical Industry, Refrigeration
Certification
RoHS, ISO, CE, CE
Condition
New, New
Nominal Capacity
0.7~59.5 Kw
Heat Exchange Area
2~170m2
Total Air Flow
430m3/H~21640m3/H
Tube Material
99.95% Pure Copper
Transport Package
Wooden Box
Trademark
Comforplanet
Origin
China
Production Capacity
50000 Piece/Year

Product Description

Finned Tube Air Cooled Heat Exchange Condenser Heat Exchanger
Finned Tube Air Cooled Heat Exchange Condenser Heat Exchanger
Finned Tube Air Cooled Heat Exchange Condenser Heat Exchanger
 
Finned Tube Air Cooled Heat Exchange Condenser Heat Exchanger
Finned Tube Air Cooled Heat Exchange Condenser Heat Exchanger
Finned Tube Air Cooled Heat Exchange Condenser Heat Exchanger
 

CFH H Type Condenser
The CFH series air cooled condensers are designed to work with the most common refrigerants. Compact-design construct and pre-wired axial fans
suitable for a variety of applications.
Fan
Factory pre-wired axial fans with wide range of size (ø200 to 600mm) which provide with optimal
ventilation and sound characteristics. Each fan is protected by steel guard.
Option: more powerful and brand name fans for special application.
Heat Exchanger
The air-cooled heat exchanger consists of inner smooth seamless copper tubes or inner-grooved
copper tubes (heat exchange area > 70 m²) arranged in staggered rows.
Option: hydrophilic coating gives better protection and longer service life against harsh conditions.
Casing
The casing of condenser is made from cold rolled steel with white powder coating.
Option: galvanized steel sheet for high resistance to corrosion.
 
Model Nominal capacity Heat Exchange Total Air Flow Total Consumed Fan Q'ty × φ(mm) Connection Inlet-Qutlet Coil Row × Coil Circuit
KW, △ t: 15K Area m²  m³/h Power, KW mm
CFH-0.7/2 0.7 2 430 35 1x200 10-10 2x4
CFH-1.2/3.4 1.2 3.4 430 35 1x200 10-10 3x4
CFH-1.4/4.0 1.4 4 430 35 1x200 10-10 3x4.5
CFH-1.6/4.4 1.6 4.4 910 60 1x250 10-10 3x5
CFH-1.9/5.2 1.9 5.2 1530 75 1x300 10-10 3x6
CFH-2.9/8 2.9 7 1530 75 1x300 12-12 4x6
CFH-3.0/8.4 3 8.4 1530 75 1x300 12-12 3x8
CFH-3.8/10.6 3.8 10.6 1530 75 1x300 12-12 4x8
CFH-3.6/10 3.6 10 1800 90 1x350 16-12 4x9
CFH-4.3/12 4.3 12 1800 120 1x350 16-12 4x10
CFH-5.4/15 5.3 15 1800 120 1x350 16-12 5x10
CFH-6.4/18 6.4 18 3000 120 1x400 16-12 6x9
CFH-7.9/22A 7.9 22 3000 120 1x400 16-12 4x8
CFH-10/27 10 27 3000 120 1x400 19-16 4x9
CFH-7.9/22B 7.9 22 3600 240 2x350 19-16 4x10
CFH-10/28 10 28 3600 240 2x350 19-14 5x10
CFH-12/33 11.9 33 6000 240 2x400 19-14 5x12
CFH-15/42 15 42 6000 240 2x400 19-14 5x12
CFH-19/52 18.7 52 6000 240 2x400 19-16 4x14
CFH-21/60 21.4 60 9000 360 2x450 22-19 4x16
CFH-25/70 24.6 70 9000 360 2x450 25-19 4x17
Finned Tube Air Cooled Heat Exchange Condenser Heat ExchangerFinned Tube Air Cooled Heat Exchange Condenser Heat ExchangerFinned Tube Air Cooled Heat Exchange Condenser Heat ExchangerFinned Tube Air Cooled Heat Exchange Condenser Heat ExchangerFinned Tube Air Cooled Heat Exchange Condenser Heat ExchangerFinned Tube Air Cooled Heat Exchange Condenser Heat Exchanger

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours